# NOTE Lines must not exceed 132 characters # Config version 1.54 # User Modifiable Parameters DO NOT EDIT WITH NOTEPAD++ THE FILE WOULD NOT WORK waterjetcutter.fill_cycle_hystersis_seconds 16.5 # prevent tank wave noise on float sensor. Default = 16.5sec. (Min-5, Max-20) waterjetcutter.filter_cleaning_seconds 80 # filter clogging variable. Default = 26.4sec. 1.5 (10m hose, 0head) 5.5 = 90 waterjetcutter.fill_cycle_seconds 100 # still in testing waterjetcutter.abrasive_hopper_timer_seconds 3600 # time to deplete dry abrasive hopper. Default = 3600sec waterjetcutter.release_pressure_seconds 0.4 # time to release the HP line pressure. Default = ~0.8 (Min = 0.3) waterjetcutter.z_height_jog_interval_checksum 10.0 # the jog interval during the setup of the cutting head height